A year of timegrapher numbers in one table

· Topics: Timegrapher

Since I have the timegrapher, every watch goes into a table before and after. Here is an extract: rate in seconds per day and amplitude in degrees, always dial up, full wind.

Measurements before and after service
Watchbeforeafter
Kienzle Markant+140 s · 190°+12 s · 235°
Glashütte Spezimaticstopped+6 s · 270°
Ruhla, date−95 s · 170°+25 s · 220°
Ruhla, blue+180 s · 160°+20 s · 215°
Junghansstoppedstill open

What I take from it:

  • Almost every watch gains 40 to 80 degrees of amplitude after cleaning and fresh oil. The old oil is nearly always the main problem.
  • Pin-lever watches rarely reach more than 230 degrees. That is normal, not a fault.
  • Numbers in one position say little. It gets interesting when you compare dial up with crown down.

The last line still says Junghans. I think it is time.