Glashütte Spezimatic, part 2: it lives

· updated · Topics: Glashütte, Repair, Timegrapher

Continued from part 1. The problem was the worn rotor bearing.

The solution came, as so often, by a detour: at the next watch fair, in May, I bought a donor movement of the same calibre for fifteen euros. The rotor bearing in it was fine.

Assembly

This time I cleaned in three baths instead of one, and dried the parts with a hand blower. For the assembly I followed my photos strictly. The reverser wheel of the automatic cost me a whole evening, because I had put it in upside down.

Result on the timegrapher, dial up, full wind:

  • Rate: +6 seconds per day
  • Amplitude: 270 degrees
  • Beat error: 0.4 ms

I admit I was very happy.

Update, 1 June: after four weeks on the wrist it gains a steady 8 to 10 seconds a day. I leave it like that. The colleague I wanted to give it back to said I should keep it. He only wears a smartwatch anyway.